Hioki-3290-10 Clamp on AC/DC HiTester
Hioki_3290-10_w

Hioki-3290-10 Clamp on AC/DC HiTester

Leverandør: Hioki E.E. Corporation
Varenummer: Hioki-3290-10
PDF Download: Hent brochuren her
Før pris: DKK 6.262,50
Total er incl. moms: DKK 4.696,25
Total er excl. moms: DKK 3.757,00
Antal:
tam_new_but2
All the Functions You Need for Measurement at DC or 1Hz and Up
 
  • Choice of three sensors (Example combinations)
    Measure up to 100 A, 200 A, or 2000 A rated current
  • Correct measurement for inverter current with AC+DC mode and True RMS rectification
  • Choice of output (Simultaneous output) Effective value, waveform, frequency, and integral value output
  • Choice of response time with three steps
  • Model 3290-10 only with integral current measurement, operating time rate measurement
 
 
 
Basic specifications (Accuracy guaranteed for 1 year, or opening and closing of the clamp sensor 10,000 times)
 
  3290 3290-10
Measurement method DC, AC+DC (True RMS), AC (True RMS/ Average rectified) DC, AC+DC (True RMS), AC (True RMS)
Peak value display Absolute value (of waveform peak) Polarities independently (±peak value of waveform, in DC mode)
Separate AC from DC output Separate constituent element of AC, DC None
Output (terminal 1) Current waveform or true RMS value (2 V / setting range), Frequency value (1 VDC / setting range) Current waveform or true RMS value (2 V / setting range)
Output (terminal 2) Rms current/Low-battery warning switch Current integral value (1 VDC / setting range)
Integral current measurement None ±, +, - integral, average value
Rate measurement None Operating time rate, total measurement time
Timer settings None 99 hr, 59 min. (for repeated up to 20 times)
Data storage None Peak, integral value, operating time rate, or other
Basic accuracy at DC current 20.00/ 100.0A (using the CT9691 sensor): ±1.3 % rdg. ±0.10 A/ ±0.5 A
20.00/ 200.0A (using the CT9692 sensor): ±1.3 % rdg. ±0.10 A/ ±0.5 A
200.0/ 2000A (using the CT9693 sensor): ±1.8 % rdg. ±1.0 A/ ±5 A
Basic accuracy at AC current
(45 to 66 Hz)
20.00/ 100.0A (using the CT9691 sensor): ±1.3 % rdg. ±0.08 A/ ±0.3 A
20.00/ 200.0A (using the CT9692 sensor): ±1.3 % rdg. ±0.08 A/ ±0.3 A
200.0/ 2000A (using the CT9693 sensor): ±1.3 % rdg. ±0.8 A/ ±3 A
Voltage measurement None
Frequency measurement 1.00Hz to 1000Hz, Basic accuracy: ±0.3% rdg. ±1dgt.
Crest factor 2.5 or later, or rated peak value of sensor
Frequency characteristic DC, or 1 Hz to 1 kHz (accuracy guaranteed range)
At monitor output: based on the using sensor
Other functions Selectable of response time, filter (fc=550 Hz)
Power supply LR6 (AA) alkaline batteries × 4, Continuous use : 22 hr, or AC adapter 9445-02/-03 (The 3290-10 only: external power supply possible)
Dimensions, mass 155 mm (6.10 in) W × 98 mm (3.86 in) H × 47 mm (1.85 in) D, 545 g (19.2 oz)
Supplied accessories Carrying strap ×1, LR6 (AA) alkaline batteries × 4, Instruction manual ×1